AND / LC-1205 Tension Loadcell

AND

Description:

 Dual guided cantilever and shear beam design for high accuracy 
 Compact, lightweight and easy to handle 
 Temperature compensation maintains both zero and span from -10 °C to +60 °C (+14 °F to +104 °F) 
 Moisture proof 
 Can be used for multi-point weighing

CapacityModel No.
20 kgfLC1205-K020
50 kgfLC1205-K050
100 kgfLC1205-K100
200 kgfLC1205-K200
500 kgfLC1205-K500
1 tfLC1205-T001A
2 tfLC1205-T002
5 tfLC1205-T005

Specification:

Rated capacities …………………………………20 kgf, 50 kgf, 100 kgf, 200 kgf, 500 kgf, 1 tf, 2 tf, 5 tf 
Rated output ……………………………………….2 mV/V±0.5% (20 kgf, 50 kgf – 1.5 mV/V ± 0.5%) 
Maximum safe overload ……………………..200% of rated capacity 
Combined error ………………………………….±0.02% of rated output 
Creep…………………………………………………..±0.1 %of rated output/hour 
Zero balance ………………………………………±2% of rated output 
Compensated 
temperature range……………………………… -10 °C to 60 °C/14 °F to +104 °F 
Recommended 
excitation Voltage ………………………………..12 V 
Maximum. 
excitation voltage …………………………………15 V 
Input terminal resistance …………………….Approximately 400 Ω 
Output terminal resistance ………………….350 Ω ± 3.5 Ω 
Insulation resistance …………………………..Greater than 5000 MΩ at DC50 V 
Temperature effect 
-Zero ……………………………………………………0.007% of rated output/°C 
-Span ………………………………………………….0.002% of rated output/°C Typ. 
Cable length ………………………………………3 m/118 inches (1, 2 & 5 t -5 m/197 inches)